FEP: Color-coded FEP Teflon® is extruded over each single conductor. The single insulated conductors are twisted and insulated with an extruded white jacket of FEP Teflon®
Key Features
- Rated for continuous use at 400° F (205º C).
- Available in nickel plated, Silver plated and Tin plated conductors.
- Available in Type 3 , 4 and 6 Conductors
- Singles: PFA Teflon®‡ 8 mil nominal
- Jacket: PFA Teflon®‡ 10 mil nominal
Comparison to Other Constructions:
Abrasion Resistance - Fair Chemical Resistance - Good Moisture Resistance - GoodFG: FG-Glass Fiberglass. Individual conductors are insulated with general purpose fiberglass and with an overall fiberglass jacket. It is Most popular and widely applied of all glass insulations. A color-coded fiberglass braid saturated with a high-performance resin is used for insulation of the single conductors and jacket. Designed for continuous use in temperatures rating up to 985 Degrees F (510 Degrees C).
Key Features
- Rated for continuous use at 985° F (510º C).
- Impregnated with high-temperature resin for better handling and reduce fraying.
- Available in standard limits and special Limits of error.
- Available in Nickel Plated Copper
PFA: Color-coded PFA Teflon® is extruded over each single conductor. The single insulated conductors are twisted and insulated with an extruded white jacket of PFA Teflon®
Key Features
- Rated for continuous use at 500° F (260º C).
- Rate for Intermittent use at 500° F (260º C).
- Available in nickel plated, Silver plated and Tin plated conductors.
- Operating Temperature –328° F (-200º C )to 400° F (205º C).
- Available in Type 3 , 4 and 6 Conductors
- Singles: FEP Teflon®‡ 8 mil nominal
- Jacket: FEP Teflon®‡ 10 mil nominal
Comparison to Other Constructions:
Abrasion Resistance - Fair Chemical Resistance - Good Moisture Resistance - GoodSingle & Multipair cables with an overall shield are constructed by insulating the single conductors with PVC. One conductor of each pair is numbered and twisted with its counterpart. The twisted pairs are cabled with an insulated copper communications wire and the entire construction is wrapped with an aluminum/Mylar tape shield. A copper drain wire is applied under the extruded PVC jacket
Key Features
- Rated for continuous use at 105° C
- High-Quality Extruded PVC single twisted conductor and Jacket with Drain wire
- Available in standard limits and special Limits of error.
- Available in Type JX, KX, RX & SX
- UL Listed, PLTC
- Rate 300 V
FEP-UL: Single pair with an overall shield are constructed by insulating the single conductors with FEP. One conductor of each pair is numbered and twisted with its counterpart. The twisted pairs are cabled with an insulated copper communications wire and the entire construction is wrapped with an aluminum/Mylar tape shield. A copper drain wire is applied under the extruded PVC jacket
Key Features
- Rated for continuous use at 200° C
- High-Quality Extruded PVC single twisted conductor and Jacket with Drain wire
- Available in standard limits and special Limits of error.
- Available in Type J, K, T, TX,JX, KX, RX & SX
- UL Listed, PLTC
- Rate 300 V
PVC-UL: Single pair with an overall shield are constructed by insulating the single conductors with PVC. One conductor of each pair is numbered and twisted with its counterpart. The twisted pairs are cabled with an insulated copper communications wire and the entire construction is wrapped with an aluminum/Mylar tape shield. A copper drain wire is applied under the extruded PVC jacket
Key Features
- Rated for continuous use at 105° C
- High-Quality Extruded PVC single twisted conductor and Jacket with Drain wire
- Available in standard limits and special Limits of error.
- Available in Type JX, KX, RX & SX
- UL Listed, PLTC
- Rate 300 V
SF: Tough, heavy insulation for use where abrasion resistance on braided insulation is required. Conductors are insulated with a braided composite synthetic yarn* & impregnated with a color-coded moisture resistant saturant. The insulated conductors are laid parallel & insulated with a heavy yarn composite synthetic fiber jacket which is then coated with the same saturant.
Key Features
- Rated for continuous use at 550° F (290º C).
- Impregnated with high-temperature resin for better handling and reduce fraying.
- Available in standard limits and special Limits of error.
- Available in Type JX, KX, RX & SX
CFCF: Highest temperature flexible insulation available. The braided yarn is a composition of the oxides of alumina, boric and silicone. Each conductor as well as the overall jacket are braided with this high temperature yarn to provide maximum flexibility at extremely high temperatures.
Key Features
- Rated for continuous use at 2200° F (1205º C).
- Rate for Intermittent use at 2600° F (1430º C).
- Impregnated with high-temperature resin for better handling and reduce fraying.
- Available in standard limits and special Limits of error.
- Available in Type J,JX K, KX, RX & SX
HFG: A high-temperature, high tensile strength fiberglass, either color-coded or with tracer yarn, is braided on both the single conductors and the overall jacket. Both are impregnated with a 500ºF modified resin saturant .
Key Features
- Rated for continuous use at 1300° F (704º C).
- Rate for Intermittent use at 1650° F (870º C).
- Impregnated with high-temperature resin for better handling and reduce fraying.
- Available in standard limits and special Limits of error.
- Available in Type J, K, JX, KX, RX & SX
FG: FG-Glass Fiberglass. Individual conductors are insulated with general purpose fiberglass and with an overall fiberglass jacket. It is Most popular and widely applied of all glass insulations. A color-coded fiberglass braid saturated with a high-performance resin is used for insulation of the single conductors and jacket. Designed for continuous use in temperatures arating up to 950 Degrees F (510 Degrees C).
Key Features
- Rated for continuous use at 950° F (510º C).
- Rate for Intermittent use at 1200° F (650º C).
- Impregnated with high-temperature resin for better handling and reduce fraying.
- Available in standard limits and special Limits of error.
- Available in Type J, K, RX & SX
KP: Polyimide is fused over each single conductor. The single insulated conductors are laid parallel and insulated with a fused polyimide jacket. Polyimide insulation is also highly effective in radiation environments, providing exceptional resistance to radiation-induced degradation. This insulation material maintains its integrity and performance even when exposed to high levels of radiation
Key Features
- Rated for continuous use at 500° F (260º C).
- Available in standard limits and special Limits of error.
- Operating Temperature –400° F (-240º C )to 500° F (260º C).
- Available in Type J, K, JX, KX, RX & SX
PFA: Color-coded PFA Teflon® is extruded over each single conductor. The single insulated conductors are laid parallel and insulated with an extruded jacket of PFA Teflon®
Key Features
- Rated for continuous use at 500° F (260º C).
- Available in standard limits and special Limits of error.
- Operating Temperature –328° F (-200º C )to 500° F (260º C).
- Available in Type J, K, JX, KX, RX & SX
- Singles: FEP Teflon®‡ 8 mil nominal
- Jacket: FEP Teflon®‡ 10 mil nominal
FEP: Color-coded FEP Teflon® is extruded over each single conductor. The single insulated conductors are laid parallel and insulated with an extruded jacket of FEP Teflon®
Key Features
- Rated for continuous use at 400° F (205º C).
- Rate for Intermittent use at 500° F (260º C).
- Available in standard limits and special Limits of error.
- Operating Temperature –328° F (-200º C )to 400° F (205º C).
- Available in Type J, K, JX, KX, RX & SX
- Singles: FEP Teflon®‡ 8 mil nominal
- Jacket: FEP Teflon®‡ 10 mil nominal
PVC: PVC insulation offers excellent resistance to chemicals and abrasion. PVC single pair thermocouple wire comes with a flame-retardant, polyvinyl chloride insulation extruded over single insulated conductors. These conductors are arranged parallel and then covered with an overall PVC jacket.
Key Features
- Rated for continuous use at 220° F (105º C).
- Available in standard limits and special Limits of error.
- Available in Type JX , KX, RX & SX, BX
- Compliant to ASTM E230, IEC 584 and ANSI MC 96.1
- Flame retardant
- UL & PLTC USA
Filter Products
Product categories
Recently viewed items
TempoTech’s Thermocouple connection heads are enclosures designed to house the thermocouple junction and provide a safe, protected environment for the connections to the temperature measurement system. These heads are typically used in industrial or scientific settings where temperature measurement needs to be done reliably and securely.
Key features:-
- Protection: They protect the thermocouple from physical damage, environmental factors like moisture, dust, or chemicals, and prevent corrosion.
- Wiring: They provide a space for wiring the thermocouple to the measuring equipment, often including terminals for easy connection and disconnection.
- Ease of Maintenance: They allow for easier replacement or servicing of the thermocouple sensor without needing to disturb the rest of the setup.
- Environmental Sealing: Many connection heads are sealed to prevent moisture or contaminants from affecting the thermocouple or wiring.